TSOM98HVEM4 - 9.8kW Outdoor Unit

TSOM98HVEM4

Teco Multi-Head Outdoor Model TSOM98HVEM4
   
Power supply Ph-V-Hz 220~240-1-50
Cooling Capacity (Indoor+Outdoor)* kW 9.85
Capacity Range kW 1.71~12.13
Power Input (Indoor+Outdoor)* kW 2.48
Rated current (Indoor+Outdoor)* A 10.94
AEER (Indoor+Outdoor)* W/W 3.88
Star Rating   3.00
Operating Range -1550
Heating  Capacity (Indoor+Outdoor)* kW 9.90
Capacity Range kW 1.78~13.02
Power Input (Indoor+Outdoor)*       kW 2.58
Rated current (Indoor+Outdoor) *   A 11.38
ACOP (Indoor+Outdoor)* W/W 3.74
Star Rating   2.50
Operating Range -1524
Max. input consumption         W 3500
Max. current                A 17
Starting current                A 4.0
Compressor  Type    Twin Rotary DC
Outdoor air flow             m3/h 3850
Outdoor noise level  dB(A) 61
Outdoor noise level (sound power)    dB(A) 69
Outdoor unit Dimension(W*D*H) mm 946 x 410 x 810
Packing  (W*D*H) mm 1090 x 500 x 875
Net/Gross weight   Kg 71/76
Refrigerant type Type    R410A (Charged for 40 metres Total Pipe Run)
Charged quantity Kg 3.3 (Additional charge is 15gm/m to Maximum Pipe Length)
Refrigerant piping Liquid side/ Gas side   4 x Φ6.35 (1/4")/
3 x Φ9.52 (3/8")                             + 1 x Φ12.7(1/2")
Max. length for all rooms 80
Max. length for one indoor unit 35
Max. height difference between indoor and outdoor unit  OU higher than IU 10
OU lower than IU 15
Max. height difference between indoor units  10
Ambient temperature cooling -1550
heating -15~24