TDS-TSO128HVBMJBE - Ducted Air Conditioner

TDS-TSO128HVBMJBE

For full details of this product, please refer to the brochure found under the downloads tab below.

Model Number Indoor TDS128HVBMJBE
Outdoor TSO128HVBMJBE
Power Supply - Indoor & Outdoor V-Ph-Hz 230 - 1 - 50
Cooling Capacity (MEPS)* kW 12.8
Total Input kW  4.09
Total Rated Current A  18.0
Heating Capacity (MEPS)* kW  15.0
Total Input kW  4.44
Total Rated Current A  19.4
Indoor Air Flow (Hi)   L/s  670
Indoor External Static Pressure (Hi)   Pa  200
Outdoor Sound Pressure   dB(A)  71
Indoor Unit Dimensions (WxHxD) mm  1200 x 380 x 550
Packing (WxHxD) mm  1475 x 420 x 655
Net/Gross Weight kg  54 / 60
Indoor Spigot Size Supply Air (WxH) mm  1000 x 253
Return Air (WxH) mm  1145 x 334
Outdoor Unit Dimensions (WxHxD) kg  938 x 1369 x 392
Packing (WxHxD) mm  1095 x 1505 x 495
Net/Gross Weight kg  100 / 114
Compressor     Rotary
Refrigerant Type     R410A
Refrigerant Piping   mm ø9.52 / ø19.05
Controller Type (Supplied Standard)   Wired Yes
  Wireless Yes
Operation Range (Indoor)   ºC 17~30
Ambient Temp. Range (Cooling / Heating)   ºC -15~50 / -15~24
  • Brochure

    • File Name
    • Brochure for TDS-TSO128HVBMJBE
  • Images

    • File Name
    • High Resolution Image - Indoor